Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Coluna/Columna ; 20(2): 127-131, Apr.-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1249653

ABSTRACT

ABSTRACT Objective: To evaluate a new treatment for split fractures through fatigue tests on a swine model. Methods: Thirty lumbar spine samples (L2-L3-L4) from swine models were divided into three test groups. The first was the control group (intact vertebrae). In the second group, a bone defect was created, similar to a coronal split fracture of the vertebral body. For this, a bone defect (osteotomy) was performed in the coronal axis of the middle third of the middle lumbar vertebral body (L3), keeping the disc-ligament structures intact. In the third group, the same procedure was performed to cause bone failure, but was associated with the use of synthesis material, with pedicular fixation using 3.5 mm cannulated screws with partial thread, in order to apply compression at the fracture site, giving resistance and support to the vertebra. The groups were submitted to biomechanical fatigue tests. The number of cycles required to failure in the specimen was analyzed. Results: The use of the synthesis material increased the resistance of the fractured vertebrae to levels equal to those of the intact vertebra for low cycles with loads of 40% of the failure load, possibly losing up to 20% of their resistance for higher cycles. Conclusions: In the vertebrae in which synthetic material was used, greater resistance to a greater number of cycles for a longer period of time was observed when compared with the fractured vertebrae, suggesting that this is an interesting method for the fixation of split-type spinal fractures. Level of evidence III; Experimental Study.


RESUMO Objetivo: Avaliar um novo tratamento de fraturas do tipo separação (split) através de ensaios de fadiga em modelo suíno. Métodos: Trinta amostras de coluna lombar (L2-L3-L4) de modelos suínos foram divididas em três grupos para testes. O primeiro constituiu o grupo controle (vértebras intactas). No segundo grupo, foi criado um defeito ósseo semelhante a uma fratura split coronal do corpo vertebral. Para tanto, criou-se um defeito ósseo (osteotomia) no eixo coronal do terço médio do corpo vertebral intermediário lombar (L3), mantendo as estruturas disco-ligamentares íntegras. No terceiro grupo, foi realizado o mesmo procedimento para causar a falha óssea, sendo associado o uso de material de síntese, com a fixação pedicular com parafuso canulado de 3,5 mm com rosca parcial, com objetivo de realizar compressão no foco da fratura e dar resistência e sustentação à vertebra. Os grupos foram submetidos a testes biomecânicos de fadiga. Foi analisado o número de ciclos necessários para que ocorresse a falha no corpo de prova. Resultados: O material de síntese aumenta a resistência da vértebra fraturada em níveis iguais aos da vértebra intacta para baixos ciclos e com cargas de 40% da tensão de ruptura, podendo perder até 20% de sua resistência para ciclos mais altos. Conclusões: Nas vértebras em que foi utilizado material de síntese observou-se maior resistência ao maior número de ciclos por um período mais prolongado em comparação com as vértebras apenas fraturadas, sugerindo que este é um método interessante para a fixação de fraturas do tipo split na coluna vertebral. Nível de evidência III; Estudo experimental.


RESUMEN Objetivo: Evaluar un nuevo tratamiento de fracturas lumbares del tipo separación (split) a través de ensayos de fatiga en modelo porcino. Métodos: Treinta muestras de columna lumbar (L2-L3-L4) de modelos porcinos fueron divididas en tres grupos para tests. El primero constituyó el grupo control (vértebras intactas). En el segundo grupo, fue creado un defecto óseo semejante a una fractura split coronal del cuerpo vertebral. Para tanto, se creó un defecto óseo (osteotomía) en el eje coronal del tercio medio del cuerpo vertebral intermedio lumbar (L3), manteniendo las estructuras disco-ligamentarias íntegras. En el tercer grupo, fue realizado el mismo procedimiento para causar la falla ósea, siendo asociado el uso de material de síntesis, con fijación pedicular con tornillo canulado de 3,5 mm con rosca parcial, con el objetivo de realizar compresión en el foco de la fractura y dar resistencia y sustentación a la vértebra. Los grupos fueron sometidos a tests biomecánicos de fatiga. Fue analizado el número de ciclos necesarios para que ocurriese la falla en el cuerpo de prueba. Resultados: El material de síntesis aumenta la resistencia de la vértebra fracturada en niveles iguales a los de la vértebra intacta para bajos ciclos y con cargas de 40% de la tensión de ruptura, pudiendo perder hasta 20% de su resistencia para ciclos más altos. Conclusiones: En las vértebras en que fue utilizado material de síntesis se observó mayor resistencia al mayor número de ciclos por un período más prolongado en comparación con las vértebras solamente fracturadas, sugiriendo que este es un método interesante para la fijación de fracturas de tipo split en columna vertebral. Nivel de evidencia III; Estudio experimental.


Subject(s)
Humans , Fractures, Bone , Spine , Models, Animal , Fatigue
2.
Coluna/Columna ; 20(1): 55-59, Jan.-Mar. 2021. tab, graf
Article in English | LILACS | ID: biblio-1154019

ABSTRACT

ABSTRACT Objective: This research presents a biomechanical analysis performed in the lumbar spine of a porcine animal model, considering a minimally invasive technique for the treatment of split fractures. Methods: Porcine spines were used to perform compression tests, considering three different approaches. Three groups were defined in order to verify and validate the proposed technique: a control group (1); spines with split fractures (2); and a treatment group (3). For the first group (control), spines were axially compressed until any kind of fracture occurred, in order to verify the strength of the structure. In the second group, split fractures were created to obtain the mechanical failure pattern of the model. In the third group, the split fractures were submitted to the proposed treatment, to verify the resistance achieved. The three groups were compared by means of axial compression tests. Statistical analysis was performed by ANOVA. Results: The control group (intact spine) and the treated split fracture group presented similar results (p>0.05), differing from the results for the untreated split fracture group (p<0.05). Conclusions: The tests performed in order to determine the behavior and strength of the lumbar spine when subjected to axial compression provided positive data for the development of a minimally invasive technique capable of restoring split fractures of the spine. Level of evidence III; Experimental research.


RESUMO Objetivo: Esta pesquisa apresenta uma análise biomecânica realizada na coluna lombar em modelo animal suíno, considerando uma técnica minimamente invasiva para o tratamento de fraturas vertebrais do tipo split. Métodos: Foram usadas colunas de suínos para a realização de testes de compressão, considerando três diferentes abordagens. Para verificar e validar a técnica proposta, foram definidos três grupos: grupo controle (1); colunas com fraturas do tipo split (2) e grupo tratamento (3). No o primeiro grupo (controle), as colunas foram comprimidas axialmente até que ocorresse qualquer tipo de fratura, a fim de verificar a resistência da estrutura. No segundo grupo, foram criadas fraturas do tipo split para obter o padrão de falha mecânica do modelo. No terceiro grupo, as fraturas do tipo split foram submetidas ao tratamento proposto, para verificar a resistência alcançada. Os três grupos foram comparados por meio de testes de compressão axial. A análise estatística foi realizada por ANOVA. Resultados: O grupo controle (coluna íntegra) e o grupo com fratura do tipo split tratada apresentaram resultados semelhantes (p > 0,05), diferentemente dos resultados do grupo com fratura do tipo split não tratada (p < 0,05). Conclusões: Os testes para determinar o comportamento e a força da coluna lombar quando é submetida à compressão axial forneceram dados positivos para o desenvolvimento de uma técnica minimamente invasiva capaz de restaurar fraturas tipo split da coluna vertebral. Nível de evidência III; Pesquisa experimental.


RESUMEN Objetivo: Esta investigación presenta un análisis biomecánico realizado en la columna lumbar de un modelo animal porcino, considerando una técnica mínimamente invasiva para el tratamiento de fracturas vertebrales del tipo split. Métodos: Fueron usadas columnas de porcinos para la realización de tests de compresión, considerando tres diferentes abordajes. Para verificar y validar la técnica propuesta, fueron definidos tres grupos: grupo control (1); columnas con fracturas del tipo split (2) y grupo tratamiento (3). En el primer grupo (control), las columnas fueron comprimidas axialmente hasta que ocurriera cualquier tipo de fractura, a fin de verificar la resistencia de la estructura. En el segundo grupo, fueron creadas fracturas del tipo split para obtener el patrón de falla mecánica del modelo. En el tercer grupo, las fracturas del tipo split fueron sometidas al tratamiento propuesto, para verificar la resistencia alcanzada. Los tres grupos fueron comparados por medio de tests de compresión axial. El análisis estadístico fue realizado por ANOVA. Resultados: El grupo control (columna íntegra) y el grupo con fractura del tipo split tratada presentaron resultados semejantes (p>0,05), a diferencia de los resultados del grupo con fractura del tipo Split no tratada (p<0,05). Conclusiones: Los tests para determinar el comportamiento y la fuerza de la columna lumbar cuando es sometida a la compresión axial suministraron datos positivos para el desarrollo de una técnica mínimamente invasiva, capaz de restaurar fracturas del tipo Split de la columna vertebral. Nivel de evidencia III; Investigación experimental.


Subject(s)
Humans , Spinal Injuries , Spine , Therapeutics , Spinal Fractures
3.
Coluna/Columna ; 19(3): 205-208, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1133584

ABSTRACT

ABSTRACT Objective To analyze the behavior of thoracolumbar fractures of the coronal split type using the finite element method. Methods Two comparative studies were conducted through simulation of coronal split fractures in a finite model in which the first lumbar vertebra (L1) was considered to be fractured. In the first case, the fracture line was considered to have occurred in the middle of the vertebral body (50%), while in the second model, the fracture line occurred in the anterior quarter of the vertebral body (25%). The maximum von Mises stress values were compared, as well as the axial displacement between fragments of the fractured vertebra. Results The stress levels found for the fracture located at half of the vertebral body were 43% higher (264.88 MPa x 151.16 MPa) than those for the fracture located at the anterior 25% of the vertebra, and the axial displacement of the 50% fractured body was also greater (1.19 mm x 1.10 mm). Conclusions Coronal split fractures located in the anterior quarter of the vertebral body incurred less stress and displacements and are more amenable to conservative treatment than 50% fractures occurring in the middle of the vertebral body. Level of Evidence III; Experimental study.


RESUMO Objetivo Analisar o comportamento das fraturas toracolombares do tipo split coronal através de elementos finitos. Métodos Foram realizados dois estudos comparativos através da simulação de fratura do tipo split coronal, em modelo finito, considerando que a primeira vértebra lombar (L1) estava fraturada. No primeiro caso, considerou-se que o traço da fratura ocorria na metade do corpo vertebral (50%), já no segundo modelo, o traço de fratura ocorria na porção anterior do corpo (25%). Foram comparados os valores de tensão máxima segundo von Mises, assim como o deslocamento axial sofrido entre os fragmentos da vértebra fraturada. Resultados Na fratura localizada ao nível da metade do corpo vertebral, os níveis de tensões encontrados foram 43% maiores (264,88 MPa x 151,16 MPa) do que aqueles na fratura a 25% no terço anterior do corpo vertebral, em que o deslocamento axial da porção fraturada também foi mais elevado (1,19 mm x 1,10 mm). Conclusões As fraturas do tipo split coronal localizadas no quarto anterior do corpo vertebral concentram menos tensões e deslocamentos, sendo mais passíveis de tratamento conservador em comparação às fraturas que ocorrem na metade do corpo vertebral. Nível de Evidência III; Estudo experimental.


RESUMEN Objetivo Analizar el comportamiento de las fracturas toracolumbares del tipo split coronal a través de elementos finitos. Métodos Se realizaron dos estudios comparativos a través de la simulación de fractura del tipo split coronal, en modelo finito, considerando que la primera vértebra lumbar (L1) estaba fracturada. En el primer caso, se consideró que el trazo de la fractura ocurría en la mitad del cuerpo vertebral (50%), ya en el segundo modelo, el trazo de la fractura ocurría en la porción anterior del cuerpo (25%). Fueron comparados los valores de tensión máxima según von Mises, así como el desplazamiento axial sufrido entre los fragmentos de la vértebra fracturada. Resultados En la fractura localizada al nivel de la mitad del cuerpo vertebral, los niveles de tensiones encontrados fueron 43% mayores (264,88 MPa x 151,16 MPa) que aquellos en la fractura a 25% en el tercio anterior del cuerpo vertebral, en que el desplazamiento axial de la porción fracturada fue también más elevado (1,19 mm x 1,10 mm). Conclusiones Las fracturas del tipo split coronal localizadas en el cuarto anterior del cuerpo vertebral concentran menores tensiones y desplazamientos, siendo más susceptibles de tratamiento conservador en comparación a las fracturas que ocurren en la mitad del cuerpo vertebral. Nivel de Evidencia III; Estudio experimental.


Subject(s)
Humans , Spine , Tensile Strength , Spinal Fractures
4.
Coluna/Columna ; 18(2): 144-150, June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011948

ABSTRACT

ABSTRACT Objective: This study aims to numerically evaluate the surgical treatment of thoracolumbar fractures, comparing the strengths between the long and short fixations using the pedicle of the fractured vertebra, taking into account the supraspinous, intertransverse, and anterior longitudinal ligaments. Methods: A numerical analysis of the techniques of long and short fixation of a thoracolumbar spine fracture was performed using computed tomography images that were converted into three-dimensional models and analyzed through the ANSYS program. The two types of treatments were analyzed considering the tensions generated in the immediate postoperative period, when the fracture has not yet been consolidated. The anterior, posterior, supraspinal and intertransverse longitudinal ligaments were added, in addition to considering different vertebral geometries. Results: Taking into account that the maximum tensile stress of the material used in the metal implant, in the case of titanium, was 960 MPa, the highest tension found in the analysis of the short instrumentation was 346.83 MPa, reaching only 36.13% of the load the material supports, being, therefore, within a safety limit. The analysis performed in the spine with long instrumentation showed the highest tension value of 229.22 MPa. Conclusions: Considering the values found and the resistance of the synthesis material used, the short and long fixation can be considered in the treatment of thoracolumbar fractures with similarity and a good safety coefficient. Level of Evidence III; Case-Control.


RESUMO Objetivo: Este trabalho tem como objetivo avaliar numericamente o tratamento cirúrgico das fraturas toracolombares, comparando a resistências entre as fixações longas e curtas usando o pedículo da vértebra fraturada, levando-se em conta os ligamentos supra-espinhal, intertransversal e longitudinal anterior. Métodos: Foi realizada uma análise numérica das técnicas de fixação longa e curta deumafratura da coluna toracolombar, utilizando-se imagens de tomografia computadorizada que foram convertidas em modelos tridimensionais e analisados através do programa ANSYS. Os dois tipos de tratamentos foram analisados considerando-se as tensões geradas no período pós operatório imediato, quando a fratura ainda não está consolidada. Foram adicionados os ligamentos longitudinal anterior, posterior, supra-espinhal e intertransversal, além de se considerar diferentes geometrias vertebrais. Resultados: Levando em consideração que a tensão máxima de ruptura do material utilizado no implante metálico, no caso o titânio, ser de 960 MPa, a maior tensão encontrada na análise da instrumentação curta foi de 346,83 MPa, atingindo apenas 36,13% da carga que o material suporta, estando, portanto, dentro de um limite de segurança. A análise realizada na coluna com instrumentação longa verificou o valor de tensão mais elevado de 229,22 MPa. Conclusão: Considerando os valores encontrados e a resistência do material de síntese utilizado, a utilização da fixação curta e longa podem ser consideradas no tratamento das fraturas toracolombares apresentando similaridade e um bom coeficiente de segurança. Nível de Evidência III; Caso-Controle.


RESUMEN Objetivo: Este trabajo tiene como objetivo evaluar numéricamente el tratamiento quirúrgico de las fracturas toracolumbares, comparando las resistencias entre las fijaciones largas y cortas usando el pedículo de la vértebra fracturada, teniendo en cuenta los ligamentos supraespinal, intertransverso y longitudinal anterior. Métodos: Se realizó un análisis numérico de las técnicas de fijación larga y corta de una fractura de la columna toracolumbar, utilizando imágenes de tomografía computarizada que se convirtieron en modelos tridimensionales y fueron analizadas con el programa ANSYS. Los dos tipos de tratamiento fueron analizados considerando las tensiones generadas en el período postoperatorio inmediato, cuando la fractura aún no está consolidada. Se añadieron los ligamentos longitudinal anterior, posterior, supraespinal e intertransverso, además de considerar diferentes geometrías vertebrales. Resultados: Teniendo en cuenta que la tensión máxima de ruptura del material utilizado en el implante metálico, en el caso el titanio, fue de 960 MPa, la mayor tensión encontrada en el análisis de la instrumentación corta fue de 346,83 MPa, alcanzando apenas el 36,13% de la carga que el material soporta, estando, por lo tanto, dentro de un límite de seguridad. El análisis realizado en la columna con instrumentación larga mostró el valor de tensión más elevado de 229,22 MPa. Conclusiones: Teniendo en cuenta los valores encontrados y la resistencia del material de síntesis utilizado, la utilización de la fijación corta y larga puede ser considerada en el tratamiento de las fracturas toracolumbares presentando similitud y un buen coeficiente de seguridad. Nivel de Evidencia III, Caso-Controle.


Subject(s)
Humans , Orthopedics , Spine , Surgical Procedures, Operative , Finite Element Analysis , Fractures, Bone
5.
Coluna/Columna ; 11(4): 283-286, out.-dez. 2012. ilus
Article in Portuguese | LILACS | ID: lil-662448

ABSTRACT

O trabalho descreve uma técnica cirúrgica de redução anterior das luxações facetárias da coluna cervical e discute as indicações para cirurgia por via anterior para as luxações da coluna cervical baixa. A técnica descrita neste artigo oferece excelentes resultados, conforme revisão bibliográfica e dos resultados do Serviço, tendo sido aplicada em até 95% dos casos de fraturas-luxações. Não será abordada a apresentação de resultados neste trabalho, apenas a descrição e discussão da técnica aberta por via anterior. Observações de quarenta e um pacientes tratados nos últimos dez anos por esta técnica demonstram bons resultados quanto a pós-operatório menos doloroso, recuperação funcional extremamente rápida e complicações pouco frequentes.


This paper describes a surgical technique for anterior reduction of the spinal facets dislocations and discusses its indications for surgery of lower cervical dislocations by anterior approach. The technique described in this article provides excellent results according to literature review and the results of the Service, having been applied to 95% of cases of fracture-dislocations. The results of this work will not be presented, but the description and discussion of the open technique by anterior approach. Observations of 41 patients treated in last 10 years have shown amazing results as less postoperative pain, extremely rapid functional recovery, and lower complication rates.


El artículo describe una técnica quirúrgica para las luxaciones facetarias de la columna cervical y discute las indicaciones para la cirugía de luxación de la columna cervical baja por lo acceso anterior. La técnica descrita en este artículo proporciona excelentes resultados según la revisión de la literatura y los resultados del Servicio, después de haber sido aplicado a 95% de los casos de fracturas-luxaciones. No serán abordados resultados, sino que únicamente la descripción y discusión de la técnica de reducción abierta por acceso vía anterior. Las observaciones en cuarenta y un pacientes operados en los últimos diez años por esta técnica muestran resultados sorprendentes con respecto a un pos operatorio menos doloroso, con recuperación funcional extremadamente rápida y complicaciones menos frecuentes.


Subject(s)
Humans , Spine/surgery , Spinal Injuries , General Surgery/methods , Cervical Vertebrae , Joint Dislocations
6.
Coluna/Columna ; 10(2): 116-120, 2011. ilus, graf
Article in Portuguese | LILACS | ID: lil-595883

ABSTRACT

OBJETIVO: Avaliar a eficácia do efeito analgésico da vertebroplastia com polimetilmetacrilato (PMMA) e da estabilização vertebral obtida nos pacientes com fraturas vertebrais patológicas e realizar uma revisão detalhada da técnica da vertebroplastia percutânea, analisando suas indicações. MÉTODOS: Análise retrospectiva de 64 procedimentos de vertebroplastia percutânea em 46 pacientes. Foram realizadas avaliações dos prontuários e das radiografias pré e pós-operatórias e em nova consulta de rotina, na qual foi aplicado o questionário de dor (escala analógica visual da dor). RESULTADOS: Entre os 46 pacientes analisados, 37 (80,4 por cento) eram do sexo feminino e 9 (19,6 por cento) do sexo masculino, com média de idade de 71 anos (desvio-padrão +/- 9,2), variando de 50 a 90 anos. Foram operados 64 níveis, com predomínio do segmento toracolombar, sendo realizadas 17 (26,6 por cento) vertebroplastias a maioria em pedículos de T12. Trinta e um pacientes (67,4 por cento) apresentaram apenas um nível fraturado, 12 (26,1 por cento) apresentaram 02 níveis operados e três pacientes (6,5 por cento) apresentaram 03 ou mais níveis operados. O diagnóstico de osteoporose foi o mais comum (33 casos, 71,7 por cento). Quanto ao alívio da dor no pós-operatório, houve um alto índice de satisfação de 90 a 100 por cento em 37 (80 por cento) pacientes. CONCLUSÃO: A vertebroplastia demonstra ser um procedimento eficaz no tratamento da dor por fratura patológica de coluna, sendo também utilizada em investigação diagnóstica (biópsia óssea). É um procedimento seguro com baixas taxas de complicações.


OBJECTIVE: This paper evaluates the analgesic effect and obtained vertebral stability of percutaneous vertebroplasty with polymethylmethacrylate (PMMA) in patients with vertebral pathological fractures, and performs a detailed revision of this technique. METHODS: A retrospective analysis of 64 percutaneous vertebroplasty procedures in 46 patients was performed. Patients were evaluated by medical records, pre and post-operative radiographs, and by pain status (visual analog pain scale). RESULTS: 37 (80.4 percent) patients were female and 9 (19.6 percent) male, with mean age of 71 years (standard deviation + / - 9.2), ranging from 50 to 90 years. Sixty-four levels were treated, with a predominance of thoracic-lumbar segment, the majority 17 (26.6 percent) of vertebroplaties at T12 pedicle. Thirty-one patients (67.4 percent) presented only one fractured level, 12 patients (26.1 percent) presented 02 levels and three (6.5 percent) presented 03 or more treated levels. Osteoporosis was the most common diagnosis (33 cases, 71.7 percent). A high satisfaction rate of 90 to 100 percent was observed to the majority of patients when considering relief of pain postoperatively. CONCLUSIONS: Vertebroplasty has proven to be an effective procedure to treat pain caused by pathological fracture, and it is also used for diagnostic investigation (bone biopsy). The technique is secure and has provided low complications rates.


OBJETIVO: Evaluar la eficacia del efecto analgésico y estabilización vertebral de la vertebroplastia con polimetilmetacrilato (PMMA) en pacientes con fracturas patológicas de la columna vertebral, y realizar una revisión detallada de la técnica de vertebroplastia percutánea, analizando sus indicaciones. MÉTODOS: Evaluación retrospectiva de 64 fracturas tratadas en 46 pacientes sometidos a vertebroplastia percutánea en el período de enero de 2000 a diciembre de 2008. Los pacientes fueron evaluados por las historias clínicas, por las radiografías pre y postoperatorias y consultas de rutina en las cuales se realizaron encuestas de dolor (escala universal visual del dolor). RESULTADOS: 37 (80,4 por ciento) eran mujeres y 9 (19,6 por ciento) eran varones, con edad promedio de 71 años (desvío estándar de + / - 9,2), que oscila entre 50 y 90 años. 64 niveles fueron operados, con predominio de lo segmento torácico-lumbar, se realizaron 17 (26,6 por ciento) la mayoría en pedículos vertebroplastia de T12. Treinta y un pacientes (67,4 por ciento) tenían sólo un nivel de fractura, 12 pacientes (26,1 por ciento) tenían 02 niveles y 03 (6,5 por ciento) pacientes tenían 03 o más niveles de fractura. El diagnóstico de osteoporosis fue el más común (33 casos, el 71,7 por ciento). Cuanto al alivio del dolor postoperatorio, hubo un alto índice de satisfacción de 90 a 100 por ciento en 37 (80 por ciento) pacientes. CONCLUSIÓN: La vertebroplastia es un procedimiento que probó ser eficaz en el tratamiento del dolor por fractura patológica de la columna, y también se utiliza con fines de diagnóstico (biopsia de hueso). Es un procedimiento seguro y tiene bajas tasas de complicaciones.


Subject(s)
Humans , Fractures, Spontaneous/epidemiology , Fractures, Spontaneous/etiology , Osteoporosis , Spine
7.
Coluna/Columna ; 10(4): 275-278, 2011. ilus
Article in Portuguese | LILACS | ID: lil-610634

ABSTRACT

OBJETIVO: Avaliar os pacientes acometidos por fraturas toracolombares e tratados por instrumentação e artrodese por acesso posterior. MÉTODOS: Foi realizada análise comparativa de duas técnicas de fixação utilizando parafusos pediculares associados à fixação curta e longa. A avaliação dos pacientes foi realizada por meio de escalas de dor (EVA, escala visual analógica), avaliação funcional (Oswestry) e por critérios clínicos e radiográficos. RESULTADOS: Foram observados 70,3 por cento pacientes do sexo masculino e 29,7 por cento do sexo feminino, com média de idade de 43 anos e tempo de seguimento médio de 39 meses. A maioria dos pacientes apresentou quadro neurológico Frankel E no momento da coleta dos dados (83,8 por cento). A grande maioria dos pacientes apresentou fraturas em L1 (51,4 por cento) do tipo A3 (63,6 por cento). Entre os pacientes incluídos na pesquisa, em 62,2 por cento foi realizada artrodese curta e em 37,8 por cento, artrodese longa. Observou-se uma média de 2,7 na escala de dor e 11,2 na escala de Oswestry. CONCLUSÃO: Não foram observadas diferenças estatisticamente significativas entre as duas técnicas quando considerados os parâmetros relacionados com dor, escala de Oswestry, idade e sexo dos pacientes.


OBJECTIVE: The study evaluates patients affected by thoracolumbar fractures, and treated by posterior instrumentation and arthrodesis. A comparative analysis of two different fixation techniques using pedicle screw fixation associated with short and long instrumentation were carried out. METHODS: Patients evaluation were performed by pain scale (VAS, visual analog scale), functional scale (Oswestry) and by clinical and radiographic criteria. RESULT: It was observed 70.3 percent men and 29.7 percent women, with mean age of 43 years and average follow-up of 39 months. Most patients had Frankel E grade at the time of data collection (83.8 percent). The majority of patients had A3 (63.6 percent) fractures at L1 (51.4 percent). Short instrumentation was performed in 62.2 percent of cases. An average of 2.7 on the pain scale and 11.2 for the Owestry was obtained in the analysis. CONCLUSION: Evaluation of techniques did not present any statistically significance.


OBJETIVO: Este estudio evalúa los pacientes afectados por fracturas toracolumbares y tratados por instrumentación posterior y artrodesis. MÉTODOS: Se realizó un análisis comparativo de dos técnicas de fijación (artrodesis corta y larga). La evaluación se realizó con las escalas de dolor (EVA), funcional (Owestry) y por criterios clínicos y radiográficos. RESULTADOS: Se observaron 70,3 por ciento varones y 29,7 por ciento mujeres, con edad promedio de 43 años y promedio de seguimiento de 39 meses. La mayoría de los pacientes tenía Frankel E en el momento de la toma de datos (83,8 por ciento). La gran mayoría de los pacientes tenía fracturas en el L1 (51,4 por ciento),tipo A3 (63,6 por ciento). Entre los pacientes incluidos en la evaluación, 62,2 por ciento realizaron artrodesis corta y 37,8 por ciento artrodesis larga. Se observó un promedio de 2,7 en la escala de dolor y de 11,2 en la escala de Owestry. CONCLUSIÓN: No hubo diferencias estadísticamente significativas entre las dos técnicas.


Subject(s)
Arthrodesis , Lumbar Vertebrae , Spinal Diseases , Spinal Fractures , Thoracic Vertebrae
8.
Coluna/Columna ; 10(4): 300-304, 2011. ilus
Article in Portuguese | LILACS | ID: lil-610640

ABSTRACT

OBJETIVOS: Avaliar comparativamente o tratamento da discopatia degenerativa cervical por discectomia e artrodese cervical via anterior utilizando placas associadas a cages ou cages em PEEK isoladamente. MÉTODOS: Foi realizado um estudo retrospectivo comparativo entre dois grupos de pacientes operados pela técnica de discectomia e artrodese cervical via anterior. Foram selecionados aleatoriamente 70 pacientes, 35 operados com o método de fixação com placas associadas a cages - denominado Grupo I - e 35 com o cage em PEEK isoladamente - Grupo II. Realizou-se anamnese, exame físico, escores de dor (escala visual e analógica da dor) e função (critérios de Odom's, SF-36, Indice de incapacidade do pescoço) o pré e pós-operatório e exames de imagem. RESULTADOS: Houve predominância de pacientes do sexo feminino em ambos os grupos, com média de idade de 55 anos no Grupo I e 47 no Grupo II. Ambos os grupos apresentaram distribuição semelhante quanto ao número de níveis operados, assim como nas complicações encontradas e escores de dor, cervicalgia e SF36 no pré e pós-operatório. Houve 97.1 por cento de fusão com 94.3 por cento de bons resultados no Grupo I e 100 por cento de fusão, com 97 por cento de bons resultados no Grupo II. CONCLUSÕES: O estudo comparativo da utilização de placas com cages e cages em PEEK isoladamente apresentou resultados semelhantes e satisfatórios para os grupos estudados, não se constatando superioridade ou inferioridade de um método com relação ao outro.


OBJECTIVES: To comparatively evaluate the treatment of cervical degenerative disc disease by anterior approach using plates associated or cages and PEEK device alone. METHODS: A retrospective study comparing two groups of patients treated by anterior arthrodesis was performed. Seventy patients were randomly selected, 35 operated using plates associated with cages - Group I - and 35 with cages in PEEK alone - Group II. Medical history was obtained as well as physical examination, pain scores (pain visual analogue score) and function scores (Odom's criteria, SF-36, Neck Disability Index) and the pre and postoperative imaging studies. RESULTS: There was a predominance of female patients in both groups, with a mean age of 55 years in Group I and 47 in Group II. Both groups showed a similar distribution of the number of levels operated, as well as the complications and pain scores, SF36 and neck disability index pre- and postoperatively. There was a fusion rate of 97.1 percent with 94.3 percent of good results in Group I and 100 percent of fusion, with 97 percent of good results in Group II. CONCLUSIONS: The comparative study of arthrodesis using anterior approach with use of plates and cages and cages in PEEK alone had similar and satisfactory results for both groups, showing no superiority or inferiority of one method over another.


OBJETIVOS: Evaluar comparativamente el tratamiento de la enfermedad degenerativa del disco cervical por discectomía y artrodesis cervical vía anterior, utilizando placas asociadas con el uso de jaulas o estas en PEEK [Poliéster-Éter-Éter-Cetona], aisladamente. MÉTODOS: fue realizado un estudio retrospectivo comparativo de dos grupos de pacientes tratados con la técnica de discectomía y artrodesis cervical vía anterior. Se seleccionaron al azar 70 pacientes, 35 operados por el método de fijación con placas asociadas a jaulas - Grupo I - y 35 con las jaulas en PEEK, aisladamente - Grupo II. Se recolectarondatos de historial clínico, examen físico, puntuaciones de dolor (escala visual y analógica del dolor-EVA) y función (criterios de Odom, SF-36, Índice de Discapacidad Cervical) del pre y posoperatorio y exámenes de imagen. RESULTADOS: Se encontró un predominio de pacientes de sexo femenino en ambos grupos, con una edad promediode 55 años en el Grupo I y de 47 en el Grupo II. Ambos grupos mostraron una distribución similar en el número de niveles operados, así como de las complicaciones encontradas y de las puntuaciones de dolor, índice de discapacidad cervical y SF36 para el pre y posoperatorio. Hubo 97,1 por ciento para la fusión y 94,3 por ciento de buenos resultados en el Grupo I y el 100 por ciento de fusión, con 97 por ciento de buenos resultados en el Grupo II. CONCLUSIONES: El estudio comparativo de la utilización de placas con jaulas y estas en PEEK, aisladamente, presentó resultados similares y satisfactorios para los grupos estudiados, sin mostrar superioridad o inferioridad de un método sobre otro.


Subject(s)
Arthrodesis , Spinal Diseases , Spinal Fusion , Spinal Injuries , Cervical Vertebrae/surgery
9.
Coluna/Columna ; 9(1): 43-48, ene.-mar. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-547867

ABSTRACT

OBJETIVO: avaliação e determinação de critérios que possam nortear o tratamento das fraturas do odontoide. MÉTODOS: foi realizado estudo retrospectivo e comparativo entre o tratamento conservador e o cirúrgico do odontoide em 24 pacientes com fratura decorrente de trauma. Os pacientes foram avaliados por meio de exame clínico e radiológico e o tratamento efetuado foi avaliado por meio de testes descritivos, distribuição de frequências e testes estatísticos comparativos. RESULTADOS: foram observados 17 pacientes do sexo masculino (70,8 por cento) e 7 do sexo feminino (29,2 por cento), com idades entre 12 e 80 anos (média de 39 anos) e seguimento pós-tratamento de 12 a 110 meses. Em relação às fraturas, não foram observadas fraturas do tipo I, 17 casos apresentaram fratura do tipo II (70,8 por cento) e 7 do tipo III (29,2 por cento), classificadas segundo Anderson e D'Alonzo. A decisão pelo tratamento cirúrgico ou conservador ocorreu em função de critérios de redução e instabilidade. Quando se decidia pelo tratamento cirúrgico, era utilizado o acesso de Southwick-Robinson, utilizando-se um parafuso canulado para a fixação da fratura. Nos pacientes tratados conservadoramente, optou-se pelo halo-gesso ou colar cervical tipo Philadelphia. Independentemente do tipo da fratura, a consolidação ocorreu em média em três meses para os pacientes tratados cirurgicamente, enquanto as fraturas tratadas conservadoramente consolidaram em torno de cinco meses. CONCLUSÕES: apesar de haver uma tendência à consolidação mais rápida quando é realizado o tratamento cirúrgico, o tratamento conservador deve ser considerado, tendo em vista os critérios de redução e instabilidade.


OBJECTIVE: this paper evaluates and determines the criteria that may guide the treatment of odontoid fractures. METHODS: a retrospective and comparative study of conservative versus surgical treatment for odontoid was carried out with 24 patients who suffered odontoid fracture due to trauma. RESULTS: seventeen males (70.8 percent) and seven females (29.2 percent) ranging from 12 to 80 years old (mean 39 years old) and followed-up from 12 to 110 months were selected for the analysis. None type I fracture was found, 17 patients had type II fractures (70.8 percent) and seven type III fractures (29.2 percent), all classified according to Anderson and D'Alonzo criterion. Decision making for surgical or conservative treatment occurred depending on reduction and instability criteria. Surgical treatment was carried out by Southwick-Robinson technique, by one cannulated screw for assuring odontoid fixation. Conservative treatment was performed with halo-vest or Philadelphia cervical collar. Independently on the fracture type, the consolidation occurred within three months for patients treated surgically and within five months for patients treated conservatively. CONCLUSIONS: the surgical treatment could determine a faster consolidation, but the conservative option must be observed since reduction and stability are obtained.


OBJETIVO: evaluación y determinación de criterios que puedan direccionar el tratamiento de las fracturas de odontoides. MÉTODOS: fue realizado un estudio retrospectivo y comparativo entre el tratamiento conservador y el quirúrgico de odontoides en 24 pacientes con fractura de odontoide subsecuente al trauma. Los pacientes fueron evaluados por medio de testes descriptivos, por la distribución de frecuencias y por testes estadísticos comparativos. RESULTADOS: fueron observados 17 pacientes del sexo masculino (70.8 por ciento) y 7 del femenino (29.2 por ciento), con edades entre 12 y 80 años (promedio de 39 años) y seguimiento post-tratamiento de 12 a 110 meses. En relación a las fracturas, no fueron observadas fracturas del tipo I, 17 casos presentaron fractura del tipo II (70.8 por ciento) y 7 del tipo III (29.2 por ciento), clasificadas según Anderson y D'Alonzo. La decisión por el tratamiento quirúrgico o conservador ocurrió en función de criterios de reducción e inestabilidad. Cuando fue decidido el tratamiento quirúrgico, se utilizó el acceso de Southwick-Robinson, utilizando un tornillo canulado para la fijación de la fractura. En los pacientes tratados conservadoramente, se optó por el halo-yeso o collar cervical tipo Philadelphia. Independientemente del tipo de la fractura, la consolidación ocurrió en promedio 3 meses para los pacientes tratados quirúrgicamente, mientras que las fracturas tratadas conservadoramente consolidaron en torno de cinco meses. CONCLUSIONES: a pesar de haber una tendencia a la consolidación más rápida cuando el tratamiento quirúrgico fue realizado, el conservador debe ser considerado, observando los criterios de reducción e inestabilidad.


Subject(s)
Humans , Fracture Fixation, Internal/methods , General Surgery , Manipulation, Spinal , Odontoid Process
SELECTION OF CITATIONS
SEARCH DETAIL